Connecting AC Input Power to the Cisco ASR 1002-F Router
1
b) Run the power cord below the handles of power supplies in slot 0 and slot 1. Make sure the power cord is hanging
loose so that it will not be disconnected from the AC power inlet as shown in the foloiwng image.
Figure 139: Cisco ASR 1002-F Router AC Power Supplies in Slot 0 and Slot 1 with Power Cord
Do not run the AC power cord through the power supply handles as shown in the following
Caution
image.
Figure 140: Incorrect Cabling on the Cisco ASR 1002-F Router AC Power Supplies
Using a cable tie for the AC power cord is optional and not necessary. However, if you attach the AC power
Note
cord to a power supply tab and then remove the AC power cord for some reason, check for any damage to
the cable after you cut off the cable tie. If the AC power cord is damaged, replace it immediately.
Four power supplies must be installed in the chassis at all times, with a minimum of two power supplies
Note
(one per zone) connected to the mains in order to power on the system and ensure sufficient cooling. The
system fans are inside the power supply units and must spin for cooling. Because all the system fans can be
powered by one power supply, the second power supply unit does not have to be powered on, but must be
connected.