Removing DC Input Power from the Cisco ASR 1001 Router
2
Step 7
Insert the exposed wire of one of the ground wire into the terminal block plug. Make sure that you cannot see any wire
lead. Only wire with insulation should extend from the terminal block.
Do not overtorque the terminal block plug captive screws. The recommended maximum torque is from 0.5
Caution
Nm (4.425 lbf in.) to 0.6 Nm (5.310 lbf in.).
Step 8
Use a ratcheting torque screwdriver to torque the terminal block plug captive screw (above the installed wire lead) to
from 0.5 Nm (4.425 lbf in. to 0.6 Nm (5.310 lbf in.) as shown in the following figure.
Figure 309: Torquing the DC Power Supply Terminal Block Plug Screws
1
Cisco ASR 1000 Series Router Hardware Installation Guide
610
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Positive (+) lead wire
Torque is from 0.5 Nm (4.425 lbf in. to 0.6 Nm (5.310 lbf
in.)