By default, a port does not operate in promiscuous mode or host mode in a VLAN.
When you use the port isolate-user-vlan vlan-id promiscuous command on a port that is operating in
promiscuous mode, the device automatically executes the undo port isolate-user-vlan command to
cancel the promiscuous mode of the port first.
If you specify an isolate-user-VLAN in the command, the switch automatically assigns the target port to
both the specified VLAN and all secondary VLANs associated with it. If you specify a
non-isolate-user-VLAN in the command, the switch assigns the target port only to the specified VLAN.
However, when the isolate-user-VLAN setting is configured for that VLAN, the switch immediately assigns
the port to all secondary VLANs associated with the isolate-user-VLAN.
In automatic assignment to the isolate-user-VLAN and secondary VLANs for an access port, the switch
also changes the link type of the port to hybrid, and sets the isolate-user-VLAN as the PVID of the port. If
the isolate-user-VLAN setting is configured later than the execution of the port isolate-user-vlan vlan-id
promiscuous command, the link type and PVID do not change until the isolate-user-VLAN setting is
configured on the VLAN specified in the command.
The link type and PVID never change on a trunk port or hybrid port in the automatic VLAN assignment
process.
After the port link type changes, the switch keeps the member attribute of the hybrid port unchanged in
the VLANs where it is already a tagged member, and automatically assigns the port to the remaining
VLANs as an untagged member.
When you execute the undo port isolate-user-vlan command, follow these guidelines:
The command cancels the promiscuous mode of a port. It does not remove an access port from the
specific VLAN, but removes a trunk or hybrid port from the specific VLAN.
If the specific VLAN has been configured as an isolate-user-VLAN and associated with secondary
VLANs, the command does not remove the port from the secondary VLANs.
Examples
# Configure access port Ethernet 1/0/1 to operate in promiscuous mode in isolate-user-VLAN 2, which
is associated with secondary VLAN 20, and then cancel the configuration.
<Sysname> system-view
[Sysname] interface ethernet 1/0/1
[Sysname-Ethernet1/0/1] display this
#
interface Ethernet1/0/1
port link-mode bridge
#
return
[Sysname-Ethernet1/0/1] port isolate-user-vlan 2 promiscuous
[Sysname-Ethernet1/0/1] display this
#
interface Ethernet1/0/1
port link-mode bridge
port isolate-user-vlan 2 promiscuous
port link-type hybrid
undo port hybrid vlan 1
port hybrid vlan 2 20 untagged
port hybrid pvid vlan 2
#
200