PLC Settings
6-3-2

Connecting to a Serial Communications Board/Unit

Front Panel Switch Settings
Words Allocated in the DM Area
CS-series Serial
Communications Board
Port 1
Port 1
D32000
D32010
D32001
D32011
106
This section describes the settings for connecting to the following Serial Com-
munications Board/Units.
Board/Unit name
Serial Communications Board
Serial Communications Unit
For a Serial Communications Unit, set the unit number. The first address for
that Unit in the DM Area will be determined as follows:
m = D30000 + 100 x unit number
Set the data in the DM Area as shown in the following table.
Words
CS/CJ-series Serial
Communications Unit
Port 1
Port 1
m
m+10
m+1
m+11
Example: When Host Link, 7-bit Data, 1 Stop Bit, Even Parity, and a Baud
Rate of 19,200 bps Are Set
CS-series Serial
Communications Board
Port 1
D32000
D32010
D32001
D32011
CS1W-SCB@@-V1
CS1W-SCU@@-V1, CJ1W-SCU@@-V1
Bit
15
1: Custom
12 to 14
Reserved.
08 to 11
5 hex: Host Link
05 to 07
Reserved.
04
Either 0 or 1 can be set.
03
0: 7 or 1: 8 bits
02
1: 1 stop bit
01
Parity
0: Parity, 1: No parity
00
Parity
0: Even, 1: Odd
04 to 15
Reserved.
00 to 03
Baud rate
0 hex: Default (9,600)
6 hex: 9,600
7 hex: 19,200
8 hex: 38,400
9 hex: 57,600
A hex: 115,200
Words
CS/CJ-series Serial
Communications Unit
Port 1
Port 1
m
m+1
Section 6-3
Model
Settings
Setting
Port 1
m+10
8504 hex
m+11
0007 hex