Configuration Settings from the System Menu
Touch Switch Adjustment
Note
Clock Settings (NV4W and NV3Q Only)
Description of Function
The default communications settings for the COM port are 9,600 and 8/1/Odd.
There is always only one stop bit.
To display the Touch Switch Adjustment Screen, touch "Setting" from the Star-
tup Screen of the System Menu and then touch "T.SW" (for the NV3W) or
"Touch SW" (for the NV3W-V1, NV4W or NV3Q) on the Setting Screen. The
locations of the touch switches on the PT can be adjusted here. Adjust the
locations as required if the touch switches become offset.
Touch Switch Adjustment
Accessing Screens
Startup Screen
[Setting]
[Touch SW]
Touch Panel Operation
Adjustment
Use an object with a soft pointed tip to touch the + marks on the
screen. Touch the screen three times according to on-screen instruc-
tions. If the locations of the touch switches are too offset, you may
have to repeat the operation. This setting is saved even if the power
supply is turned OFF. It is initialized if the internal Flash Memory is
initialized.
Returning
The previous screen will not return until the adjustment is complete.
The NV-series PTs use analog touch panels. As the panels age, the positions
of the touch switches can change. Calibrate the touch switches if the positions
of the touch switches change too much.
Touch "Clock" from the Setting Menu of the System Menu to access the Clock
Screen. The time of the clock in the PT can be set here.
Clock Setting Screen
Accessing Screens
Startup Screen
[Clock]
The current PT clock time will be displayed on the screen. Touch the Up and
Down Keys to change the values of the items to be changed (year, month,
day, hour, minutes, seconds).