Procedure - Precor Experience Series 800 line EFX Service Manual

Table of Contents

Advertisement

Procedure

Review entire procedure before starting.
1. Remove the Drive Access Cover, see
2. Remove the left drive disk cover, see
3. Place the belt tension gauge onto the First Stage Drive Belt midway between the two
pulleys and measure the tension. If the tension is within specification, belt tension adjust-
ment is not required. If the tension is not within [[[Undefined variable EFX800-
16Base.spec-BeltTensionFirstStage-12]]] continue with the belt tension adjustment.
4. Use a 1/2" socket to loosen the two Drive Components Assembly fastener nuts (left
Experience Series 800 Line EFX
First Stage Drive Belt Tension Adjustment
"Drive Access Cover Replacement" on
"Drive Disk Covers Replacement" on
4 Adjustment Procedures
page 56.
page 57.
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Efx800-16 base

Table of Contents