2    Operation Verification
This section provides a method of verifying that the machine is operating correctly and can be
returned to service. Do this operation verification at the end of a maintenance procedure or
whenever it is necessary to ensure that the machine is operating properly.

Operation Verification Tests

Perform this procedure and tests to verify proper operation of the unit (use the
fication Checklist" on the next page
1. Error Code Verification
Verify that there are no current error codes or issues with the unit.
a. Go to the Error Log (or Event Log) to review any logged error codes. Resolve any
relevant active error codes,
b. P10, P30 consoles: Clear the error log; select a logged error and then hold down
the QUICK START key until the "NO ERRORS" message shows. Repeat pro-
cess until all error codes are deleted.
TIP: Error Log Delete Short Cut:
Press and hold the PAUSE/RESET key for a minimum of 6 seconds to open the Error
Log and view all logged error codes. If there are no logged error codes, the "Stuck
Key" message will show. To remove error codes, select the error code and press/hold
the QUICK START key until the "NO ERRORS" message shows.
Note: P62, P80, P82 consoles: Error codes are stored in the Event Log (Access
Hardware Validation ( 5,1,7,6,5,7,6,1) > select Settings > About > Event Log).
Unlike earlier model consoles, the error codes cannot be manually removed.
1. Hardware Validation Tests:
Access the diagnostics Hardware Validation Tests (access code 5,1,7,6,5,7,6,1) and
run the following tests:
a. DISPLAY TEST (select DISPLAY TEST): Follow prompts to run test.
b. KEYPAD TEST (select KEYPAD TEST): Follow prompts to run test.
c. HEART RATE TEST (select HEART RATE TEST): Follow to and run test.
d. CROSSRAMP TEST (select MACHINE TEST > CROSSRAMP TEST ):
i. Use the incline control to verify the incline level 1 and level 20 A/D values,
level 1 = [[[Undefined variable EFX800-16Base.spec-LifMotorAD1]]] and
level 20 = [[[Undefined variable EFX800-16Base.spec-LiftMotorAD20]]].
ii. Use the incline control to set the incline level to 20 and verify the A/D value
is [[[Undefined variable EFX800-16Base.spec-LiftMotorAD20]]].
Exit: Press the RESET key to exit diagnostics. On P82 consoles, press Back to
l
exit diagnostic and return to the Home page.
2. Operational Check:
Select the Manual program and operate the elliptical for at least 5 minutes. While
Experience Series 800 Line EFX
to track results):
see"Error Log & Event Log" on
2 Operation Verification
Operation Verification Tests
"Operation Veri-
page 131.