Depending on the error code type, after the end of a workout, the solid yellow light will
either revert back to blue (or pulsing blue), or require the operator to do a manual reset
from the service menu.
Maintenance counter operation: The counter starts at 250 hours and counts down the
l
hours of active use to 0 hours. When the counter reaches zero, the ASL will begin
pulsing blue indicating preventative maintenance is due.
Viewing the ASL light
l
When in active use with exerciser striding.
o
When the exerciser presses the Wakeup switch located on the rear of the unit.
o
For 90 seconds after the exerciser ceases striding.
o
For 90 seconds after the Wakeup switch is pressed.
o

ASL States

The ASL utilizes a combination of blue and yellow lights to indicate the current operational
machine status.
ASL State
OFF
The unit is powered OFF or there is no power to the LPCA or some other hard fail-
ure. On P10, P20, and P30 consoles the ASL brightness is set to OFF.
Blue Solid
Normal operation Indicates that the ASL has not detected any logged error
codes.
Blue Pulsing
Preventative maintenance reminder.
Treadmills: A belt rating of 0 or 1 will cause a blue pulsing ASL light indicating
that there is a problem with the running belt/deck and is in need of servicing or
replacement.
Ellipticals: The maintenance counter starts at 1000 hours and counts down the
active use hours to 0. When the counter reaches zero hours, the ASL will begin
pulsing blue indicating preventative maintenance is due.
Yellow Solid
Indicates an error has occurred, was self-corrected and the machine can be
used. The fault can be cleared.
Experience Series 800 Line EFX
DESCRIPTION
6 Troubleshooting
Active Status Light (ASL)
135