Sc600 (Controller) - Ricoh MP C2504 Field Service Manual

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

No.
Description
16 - 19 Communication error
(interrupted)
21 - 24 Communication timeout
26 - 29 Device stops (logically)
31 - 34 Full of buffer (request)
36 - 39 Verification error
SC No.
Type
SC687-00
D

SC600 (Controller)

SC No.
Type
SC632-00
D
Noise, Incorrect connection
Noise, Incorrect connection, Malfunction
Noise, Incorrect connection, Malfunction
Noise, Incorrect connection, Malfunction
Noise, Incorrect connection
Error Name/Error Condition/Major Cause/Solution
PER Not Received Error
Unable to receive the PER command from the controller.
Communication error
Replace the BCU.
Error Name/Error Condition/Major Cause/Solution
Counter device error 1
After 3 attempts to send a data frame to the optional counter device via
the serial communication line, no ACK signal was received within 100
ms.
Serial line between the optional counter device, the relay board and
copier control board is disconnected or damaged.
• Turn the main power off/on.
• Check the serial communication line.
Service Call 620-687
Cause
Retry
3
3
3
3
2