6. Troubleshooting
No.
[0x5032]
[0x5245]
918
Type
Error Name/Error Condition/Major Cause/Solution
HAIC-P2 error
HAIC-P2 decompression error (An error occurred in the ASIC
compression/decompression module.)
• The code data saved in the HDD was broken for an unexpected
reason. (HDD device defective)
• The code data saved to memory was broken for an unexpected
reason. (Memory device defective)
• ASIC defective
• Data other than code data was unzipped due to a software
malfunction.
• Turn the main power OFF/ON.
• Replace the HDD.
• Replace the memory
• Replace the controller board.
• Fix the software
Link up error
Link up transaction between Engine ASIC and Veena was not completed
within 100 ms.
Either one of following message appears on console if Link up error
occurs.
RESUME:PCI-Express bus ROOT_DL status error
RESUME:PCI-Express bus DETUP status error
"0x53554D45" -> Link up error
Also, error code "0x5245" and detail code ""0x53554D45" -> Link up
error" appears on operation panel.
• Turn the main power OFF/ON.
• Replace the controller board or the engine board (IPU, BCU)