No.
Type
[0x5355]
L2 status time out
L2 status register between Engine ASIC and Veena was not reached the
target value within 1 sec.
Engine ASIC during operation was rebooted or shifted to energy saving
mode.
Machine reboots when SC23x, SC30x occurs.
If Engine ASIC is working when rebooting (or shifting to the energy saving
mode), L2 status value is not on target.
The following message appears on console.
SUSPEND:PCI-Express L2 Status Check Error
SUSPEND:PCI-Express L2 Status Check Error
Also, error code "0x5355" and detail code ""0x5350454E44" -> L2
status time out" appears on operation panel.
[0x6261]
HDD defective
Received file system data was broken even if the initialization succeeds
and there was no error reply from the HDD.
Power supply disconnection during data writing to the HDD.
Replace the HDD.
This SC may occur when turning on the machine for the first time with a
new HDD. In this case, turn the main power off/on.
[0x696e]
gwinit processing end
If the SCS process is ended for some reason
If an unexpected error occurs at SCS processing end, gwint processing
also halts (this result is judged a kernel stop error, by gwinit specification)
"0x69742064" -> "init died"
Turn the main power OFF/ON.
Error Name/Error Condition/Major Cause/Solution
• Turn the main power OFF/ON.
• Replace the controller board or the engine board (IPU, BCU)
Service Call 816-899