Crisis Management When Temperature Rises In The Machine; Overview Of Cooling Operation In The Machine; Cooling Operation During Output - Ricoh MP C2504 Field Service Manual

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

7. Detailed Descriptions

Crisis Management When Temperature Rises in the Machine

In order to suppress excessive temperature rise in the machine and maintain equipment quality, a
temperature sensor (imaging temperature sensor (thermistor)) [A] is installed in the machine. The imaging
temperature sensor (thermistor) detects the temperature environment in the machine, and controls
cooling operation.

Overview of cooling operation in the machine

The temperature in the machine is detected during output and after output, and the interior of the
machine is cooled by fan operation (stepwise operation of fan, prolonged fan rotation after paper
has passed through) according to the temperature inside the machine.
However, if the temperature inside the machine rises significantly due to passing a large volume of
paper, in addition to fan operation, the CPM is specified to control the temperature in the machine.

Cooling operation during output

Perform cooling operation under the following conditions.
Imaging temperature
Fusing exhaust fan
Ozone exhaust fan
Toner supply cooling fan
Development intake fan
PSU cooling fan
The operation start temperature can be modified by SP.
1206
Less than
34
ON
20%
-
*3
-
*2
ON
34
35
36
ON
ON
ON
20%
30%
30%
-
-
ON
-
-
ON
ON
ON
ON
*1
37
38
40
ON
ON
ON
40%
40%
40%
ON
ON
ON
ON
ON
ON
ON
ON
ON