7. Detailed Descriptions
Displays the number of sheets interval for Interrupt Pro-Con (FC).
• SP3-533-013 (Interrupt ProCon :Set: Corr(Short):FC)
Specifies the correcting coefficient (Short) of number of sheets interval for Interrupt Pro-Con (FC).
• SP3-533-014 (Interrupt ProCon :Set: Corr(Mid):FC)
Specifies the correcting coefficient (Mid) of number of sheets interval for Interrupt Pro-Con (FC).
• SP3-534-001 (JobEnd ProCon :Set: Interval:Set:BW)
Specifies the number of sheets interval for Job end Pro-Con (BW).
• SP3-534-002 (JobEnd ProCon :Set: Interval:Disp:BW)
Displays the number of sheets interval for Job end Pro-Con (BW).
• SP3-534-003 (JobEnd ProCon :Set: Corr(Short):BW)
Specifies the correcting coefficient (Short) of number of sheets interval for Job end Pro-Con (BW).
• SP3-534-004 (JobEnd ProCon :Set: Corr(Mid):BW)
Specifies the correcting coefficient (Mid) of number of sheets interval for Job end Pro-Con (BW).
• SP3-534-011 (JobEnd ProCon :Set: Interval:Set:FC)
Specifies the number of sheets interval for Job end Pro-Con (FC).
• SP3-534-012 (JobEnd ProCon :Set: Interval:Disp:FC)
Displays the number of sheets interval for Job end Pro-Con (FC).
• SP3-534-013 (JobEnd ProCon :Set: Corr(Short):FC)
Specifies the correcting coefficient (Short) of number of sheets interval for Job end Pro-Con (FC).
• SP3-534-014 (JobEnd ProCon :Set: Corr(Mid):FC)
Specifies the correcting coefficient (Mid) of number of sheets interval for Job end Pro-Con (BW).
• SP3-539-001 (Dev Agitating Time :Set: Time)
Specifies the developer agitating time.
• SP3-600-002 (Select ProCon: LD Control)
Specifies the LD control mode.
0:OFF, 1:ON
• SP3-600-030 (Select ProCon: IBACC:ON/OFF)
Specifies ON/OFF of IBACC.
0: OFF, 1: ON