3. Engine SP Mode Tables
1-116-011 Time Out
1-116-012 Time Out:Energy Saving
1-116-021 Delay:Standard Speed:FC:1
1-116-022 Delay:Standard Speed:BW:1
1-116-023 Delay:Mid. Speed:FC:1
1-116-024 Delay:Mid. Speed:BW:1
1-116-025 Delay:Low Speed:FC:1
1-116-026 Delay:Low Speed:BW:1
1-116-031 Delay:Standard Speed:FC:2
1-116-032 Delay:Standard Speed:BW:2
1-116-033 Delay:Mid. Speed:FC:2
1-116-034 Delay:Mid. Speed:BW:2
1-116-035 Delay:Low Speed:FC:2
1-116-036 Delay:Low Speed:BW:2
1-116-041 Press Reference Temp.
1-116-042 Temp. Correction Lower Limit
1-116-043 Temp. Correction Upper Limit
1-116-044 Press Reference Temp.:Energy
1-116-045 Temp. Corr. Lower Limit:Energy
1-116-046 Temp. Corr. Upper Limit:Energy
1-116-051 Paper Thickness
1-116-052 Paper Thickness
90
Saving
Saving
Saving
Coefficient:Plain1
Coefficient:Plain2
*ENG [0 to 500 / 10 / 1sec/step]
*ENG [0 to 500 / 10 / 1sec/step]
*ENG [0 to 20000 / 3590 / 1msec/step]
*ENG [0 to 20000 / 1320 / 1msec/step]
*ENG [0 to 20000 / 3590 / 1msec/step]
*ENG [0 to 20000 / 1320 / 1msec/step]
*ENG [0 to 20000 / 7180 / 1msec/step]
*ENG [0 to 20000 / 2640 / 1msec/step]
*ENG [0 to 20000 / 3590 / 1msec/step]
*ENG [0 to 20000 / 1320 / 1msec/step]
*ENG [0 to 20000 / 3590 / 1msec/step]
*ENG [0 to 20000 / 1320 / 1msec/step]
*ENG [0 to 20000 / 7180 / 1msec/step]
*ENG [0 to 20000 / 2640 / 1msec/step]
*ENG [0 to 200 / 86 / 1deg/step]
*ENG [-30 to 0 / 0 / 1deg/step]
*ENG [0 to 30 / 4 / 1deg/step]
*ENG [0 to 200 / 75 / 1deg/step]
*ENG [-30 to 0 / -1 / 1deg/step]
*ENG [0 to 30 / 0 / 1deg/step]
*ENG [-100 to 100 / * / 1/step]
*MP C2004: -20
*MP C2504: -30
*ENG [-100 to 100 / -40 / 1/step]