Mitsubishi L02CPU User Manual page 290

Melsec-l series
Hide thumbs Also See for L02CPU:
Table of Contents

Advertisement

Item
Module Synchronization
*2
Built-in CC-Link Setting
Common Pointer No.
System Interrupt Setting (Fixed
Scan Interval)
Interrupt Program/Fixed Scan
Program Setting
Service Processing Setting
CPU Module Change Setting
*1
Setting of only a PAUSE contact is not allowed.
*2
For the L02CPU, this item cannot be set because it does not support the built-in CC-Link function.
288
Parameter
Description
No.
Select whether to synchronize
CPU module startup with
100C
H
intelligent function module
startup.
Select whether to use the built-in
1018
H
I/O
Set the start number of common
1005
H
pointers.
Set each execution interval for
1008
H
the interrupt pointers (I28 to I31).
Select whether to enable or
disable high speed execution of
1008
H
interrupt programs or fixed scan
execution type programs.
Select any of the following.
• Execute the process as the
scan time proceeds
• Specify service process time
1013
H
• Specify service process
execution counts
• Execute it while waiting for
constant scan setting.
Set items required when
performing the CPU module
1017
H
change with SD memory card
function.
Setting range
Selected/deselected
Selected/deselected
P0 to P4095
0.5ms to 1000ms
(In increments of 0.5ms)
Selected/deselected
• 1 to 99% (in increments of
1%)
• 1 to 10 (in increments of 1
time)
• 0.2 to 1000ms (in increments
of 0.1ms)
• Blank
• Backup Start Setup Contact
• Backup Start Contact
• Backup Target Data
• Title Setting
Default
Reference
Page 85,
Selected
Section 3.5
MELSEC-L
CC-Link
System
Selected
Master/Local
Module User's
Manual
Page 272,
Section 5.9.2
• I28: 100.0ms
• I29: 40.0ms
Page 273,
• I30: 20.0ms
Section 5.10
• I31: 10.0ms
Page 257,
Deselected
Section 5.5.3
Execute the
process as the
Page 88,
scan time
Section 3.6
proceeds: 10%
Page 166,
Section 3.30