4. Replacement and Adjustment

Fusing

• Because there is a danger of burns on contact with hot parts of the fusing unit, start work when the
temperature drops to a low enough temperature.
• Turn off the main power switch and disconnect the power cord before you start any of the
procedures in this section. (page 35 "General Cautions")

Fusing Unit

1.
Open the rear cover [A].
2.
Release the lock levers [B].
3.
Fusing Unit [A]
• For PM: Install a fusing unit with new product detection capability from the Maintenance Kit. (User
operation)
64