Ricoh Gim-MF1a Field Service Manual page 238

Table of Contents

Advertisement

3. Appendices: SP Mode Tables
2-961-002
Level 2
[Duty Control]
2990
Correction values of printing interval control in order to avoid the increasing
temperature from continuous printing.
2-990-001
Counter
2-990-002
Lower
2-990-003
Upper
2-990-004
OFF/ON
2-990-005
Accumulation
2997
[PCDU STOP]
2-997-001 End Mgn Distance
2998
[Timing Control]
2-998-001
T:ReverseRotation
2-998-002
T:MotorStop
2-998-003
T:NormalRotation
42
E
[0 to 1 / 0 /1 / step]
E
[0 to 65535 / 0 /1count / step]
E
[2000 to 60000 / 14400 /1count / step]
E
[2000 to 60000 / 158400 /1count / step]
E
[0 to 1 / 0 /1 / step]
E
[0 to 65535 / 0 /1count / step]
[100000 to 960000000 / 10490000 /
10000mm/ step]
The parameter which is used to calculate the
print stop end threshold [mm]. "Print stop end
E
threshold [mm]" = "End threshold (distance)
[mm]" + "End margin (distance) [mm]"
* "+1 [kp]" = "+650000 [mm]" (Add
approximately 650000 [mm] to increase the
end distance by 1 [kp])
[1 to 100 / 32 / 1msec/step]
E
Adjusts the reverse rotation time of PCU
reverse rotation.
[550 to 1000 / 550 / 50msec/step]
E
Adjusts the stop rotation time of PCU reverse
rotation.
[1 to 100 / 29 / 1msec/step]
E
Adjusts the normal rotation time of PCU
reverse rotation.