2-411-002
AH_MH
[Supply Speed]
2924
For circulating the time to supply certain amount
2-924-001
Remaining H:240
2-924-002
Remaining M:240
2-924-003
Remaining L:240
2-924-004
Remaining H:182
2-924-005
Remaining M:182
2-924-006
Remaining L:182
2925
[Toner Supply]
2-925-001
consumed amount
2-925-002
Supply Threshold
2-925-003
Sup- Coefficient
2926
[Recovery Supply]
2-926-001
Recovery Amount
2-926-002
Mixing Time
[11.0 to 30.0 / 15.0 / 0.5g/m
Displays and adjusts the threshold under
E
mid/high humidity on environment section in
regard to control the Environment Correction.
E
[0.01 to 1.00 / 0.35 / 0.01g/sec/step]
E
[0.01 to 1.00 / 0.29 / 0.01g/sec/step]
E
[0.01 to 1.00 / 0.22 / 0.01g/sec/step]
E
[0.01 to 1.00 / 0.25 / 0.01g/sec/step]
E
[0.01 to 1.00 / 0.21 / 0.01g/sec/step]
E
[0.01 to 1.00 / 0.17 / 0.01g/sec/step]
[0.0 to 100000.0 / 0.0 / 0.1mg/step]
E
Counter for judging to supply toner during
printing.
[1.0 to 100000.0 / 300.0 / 0.1mg/step]
E
Threshold for judging to supply toner during
printing.
[0.0 to 5.0 / 0.7 / 0.1/step]
E
Coefficient for calculating toner amount to
supply during printing.
[0 to 300 / 5 / 1g/step]
E
Amount for Recovery Supply.
[0 to 300 / 10 / 1sec/step]
E
Idle time to mix for Recovery Supply.
Main SP Tables-2
3
/step]
37