Ricoh Gim-MF1a Field Service Manual page 153

Table of Contents

Advertisement

SC No.
Level
SC551-00
A
SC No.
Level
SC553-01
A
SC553-02
Error Name/Error Condition/Major Cause/Solution
Broken fusing (End) thermistor wire
At least ten times, the temperature is detected to stay at -20 deg C or less
for 5 seconds.
• Broken thermistor wire
• Bad connector contact
• Clear the SP: fusing SC.
• Check the connector connection.
• Replace the fusing (End) thermistor.
Error Name/Error Condition/Major Cause/Solution
Fusing (End) thermistor high-temperature detected (software)
(553-01)
In a condition of 235 degrees C or higher temperature, the temperature
has increased more than 10 degrees C per 1 second, the heater has
continuously reached 100% (maximum) duty, and the center thermistor
has detected the failure to reach the target temperature by 11 degrees C.
(553-02)
The temperature is detected to stay at 245 deg C or higher for one
second.
• Shorted triac
• Failed Engine Board
• Clear the SP: fusing SC.
• Replace the PSU.
• Replace the Engine Board.
Service Call
151

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Gim-mf1bM173M172