V1: Feedrates
17.4 Feedrate control
17.4.2
Feedrate disable and feedrate/spindle stop
General
The feedrate disable or feedrate/spindle stop brings the axes to a standstill with adherence to the braking
characteristics and the path contour (exception: G33 block).
References:
/FB1/ Function Manual, Basic Function; Continuous-Path Mode, Exact Stop and Look Ahead (B1)
"Feedrate disable" DB21, ... DBX6.0
Interface signal "Feedrate disable" (DB21, ... DBX6.0) shuts down all axes (geometry and auxiliary axes) of a
channel in all modes.
Activation of channel-specific feedrate disable
If G33, G34, G35 active:
If G63 active:
If G331, G332 active:
"Feed stop" DB21, ...DBX12.3 geometry axes
Interface signals "Feed stop" (DB21, ... DBX12..3 and the following signals) for geometry axes 1, 2, and 3 stop
the geometry axes of a channel in JOG mode.
"Feed stop" DB31, ...DBX4.3 axisspecific
The axis-specific "Feed stop" interface signal (DB31, ... DBX4.3) is used to stop the relevant machine axis.
In automatic mode:
•
If the "Feed stop" is performed for a path axis, all the axes traversed in the current block and all axes
participating in the axis group are stopped.
•
If the "Feed stop" is performed for a positioning axis, only this axis is stopped.
Only the current axis is stopped in JOG mode.
Activation of axis-specific function "Feed stop"
Active in G33, G34, G35
For active G63
In active G331, G332
Axis/spindle disable" DB31, ... DBX1.3
Activating "Axis/spindle disable" (DB31, ...DBX1.3) disables the axial PLC interlocks "No controller enable" and
"Feed stop".
The axial and channelspecific override, however, is active.
1390
Not effective
Effective
Effective
Effective
(causes contour deviations)
Effective
Effective
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Basic Functions