DEVELOPMENT

6.4.4 DEVELOPER

[A]
G035R404.WMF
1. Remove the development unit and place it on a clean sheet. (See Development
Unit.)
2. Remove the development roller. (See Development Roller.)
3. Turn over the development unit (the development filter [A] must be at the top as
the unit turns over, as shown) and empty all the old developer [B]. Make sure
that no developer remains on the development roller or in the unit.
NOTE: 1) Dispose of the used developer in accordance with local regulations.
2) Be careful not to nick or scratch the development roller.
4. Pour all the new developer [C] into the development unit. Then, rotate the gear
[D] to distribute the developer evenly.
G035
[B]
[C]
6-14
[D]
G035R405.WMF