Ricoh G035 Service Manual page 293

Table of Contents

Advertisement

Amber
Green
(upper)
(lower)
Blinks
Blinks 3 times,
then stays on
Blinks rapidly
Blinks for 10 s,
Blinks
then goes off
Blinks rapidly 4
times, then off
Blinks rapidly
Blink alternately
SM
Status
On
Normal
On
Normal
Normal
Initialization
Error
Initialization
Error
Error
Error
NVRAM reset
7-23
SERVICE CALL CONDITIONS
Condition(s)
• The NIB is receiving a packet from
the Ethernet.
• The machine has just been turned
on. The NIB then initializes itself.
• The NIB is waiting for a print job.
• The NIB has finished initialization,
and will print a status sheet.
• The NIB detected a bad RAM chip
during initialization.
• Turn the machine off and on. If the
NIB detects the same error again,
replace the NIB.
• The NIB detected a data error in the
flash ROM (firmware) during
initialization.
• Recover the firmware by
downloading it through the network.
• The NIB detected an Ethernet
hardware error.
• Check the Ethernet connections and
restart the machine. If the error is
frequent, try replacing the NIB.
• The NIB has lost connection to
NetWare file server(s).
• Check the cable connection and the
NetWare server status.
• The NIB has reset its NVRAM to the
factory defaults. (Refer to section
4.5.1 for how to reset the NVRAM.)