(4) Detaching and refitting the laser scanner unit

Take the following procedure when the laser scanner unit is to be replaced.
Procedure
1. Remove the developing unit and drum unit
(see pages 1-5-28 and 1-5-25).
2. Remove the right lower cover and front left
cover (see pages 1-5-5 and 1-5-12).
3. Remove four screws and remove the front
right cover.
4. Remove three screws and remove the top
tray.
5. Remove five screws and remove the inner
cover.
1-5-22
Screws
Front right cover
Figure 1-5-43
Screws
Top tray
Figure 1-5-44
Screws
Screw
Screw
Inner cover
Screw
Figure 1-5-45
Screw
Screw
Screw