16. Remove the stop ring and slide the MP for-
warding pulley with the forwarding pulley
retainer from the shaft to remove it.
17. Replace the MP separation, MP paper feed
and MP forwarding pulleys.
18. Install the MP forwarding pulley to the MP
forwarding pulley shaft.
19. Refit the MP forwarding pulley shaft to the
MP unit.
20. Install the MP paper feed pulley to the MP
unit.
21. Refit the MP unit cover to the MP unit.
When refitting the MP unit cover, the films
on the cover are positioned under the MP
paper feed pulley shaft.
22. Install the MP separation pulley to the MP
unit.
23. Refit the MP unit.
24. When the MP forwarding pulley, MP paper
feed pulley or the MP separation pulley is
replaced, perform maintenance mode U901
to clear the counter value (see page 1-3-96).
Stop ring
MP forwarding pulley
Forwarding pulley
retainer
Figure 1-5-21
MP paper feed pulley shaft
Films
Figure 1-5-22
2KR/2KS
1-5-9