(2) Detaching and refitting the MP separation, MP paper feed and MP forwarding pulleys
Follow the procedure below to replace the MP separation, MP paper feed and MP forwarding pulleys.
Procedure
Removing the MP unit
1. Remove four screws and remove the right
lower cover.
2. Remove two screws and two MP holder
plates.
3. Remove two pins, two screws and two con-
nectors, and then remove the MP unit.
Removing the MP separation pulley
4. Reverse the MP unit and remove the spring
and stop ring from the MP separation pulley
shaft and move the bushing inside.
Screw
Right lower cover
Figure 1-5-9
MP unit
Pin
MP holder plate
Figure 1-5-10
Bushing
MP separation
pulley shaft
Spring
Figure 1-5-11
2KR/2KS
T 1
O P
Screws
T 1
O P
Connectors
Pin
MP holder
plate
Screw
Screw
Stop ring
1-5-5