Sub-Network Health And Status Branch - Paradyne COMSPHERE 3910 Installation And Operation Manual

3900 series point-to-point/multipoint modems
Hide thumbs Also See for COMSPHERE 3910:
Table of Contents

Advertisement

BlksErrd=xxxxxxx displays the number of blocks of data found in error (block size is 1000 bits
per block). BlksRcvd=xxxxxxx displays the total number of blocks of data received. The message
NoSync appears as a value for BlksErrd while the modem's receiver is synchronizing. The
message OvrFlw appears as the value for BlksErrd if the counter overflows.
Press the
The Pattern test can be exited and reentered without restarting the test. The BlksErrd and BlksRcvd
continue counting.
If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the
test. If it is disabled, the test operates until aborted. For more information on the Test Timeout
configuration option, refer to the Test section in Chapter 4.
To exit this function and remain in the Test branch, press the
Top-Level menu, press the

Sub-Network Health and Status Branch

The Sub-Network Health and Status (SubHS) function is not available on multipoint
tributary modems or with certain modulations (V.29, V.33, V.22bis, and V.27bis).
The SubHS branch of the Top-Level menu allows you to display alarm conditions in downstream
modems.
Status
Configure
To access the SubHS branch from the Top-Level menu, make the following selections:
Press the
3910-A2-GN32-30
key to display BlksRcvd=xxxxxxx, number of blocks of data received.
key.
Plist
Control
Test
SubHS
Leased:19.2
Test
SubHS
F1
F2
key until SubHS appears. Select SubHS.
If there are no modems in the multipoint poll list, the message Poll
List Empty! appears on the second line of the LCD.
November 1996
"Status"
Call_Setup
F3
NOTE
DCP Operation
key. To exit and return to the
Tlk/Data
Security
Remote
3-53