Vf Thresholds Update - Paradyne COMSPHERE 3910 Installation And Operation Manual

3900 series point-to-point/multipoint modems
Hide thumbs Also See for COMSPHERE 3910:
Table of Contents

Advertisement

COMSPHERE 3900 Series Modems
As data banks are transferred, the local and remote LCD's bottom line displays the status of the
download process, and the number of records sent versus the total number of records for that bank.
For Single download applications, if the download is successful, the local modem displays
Remote Clone OK and the remote modem displays Frmware Upgrade. If the download took
place over the dial network, the modems disconnect when the download is complete.
If the Single download is unsuccessful, RemClone Failed appears on the LCD's top line. Attempt
another download from the local modem. If this fails, contact your service representative.

VF Thresholds Update

The VF Thresholds Update function allows you to set the thresholds that determine the Health and
Status alarm conditions for the VF parameters. The following thresholds may be edited: RSL
High, RSL Low, Sig/Noise, NonLinear, Retrains/15min, Signal Quality, Near Echo, and Far
Echo. (For Health and Status alarm conditions, refer to Table 3-6 in the Device Health and
Status (DeviceHS) section of this chapter.)
To access VF Thresh Update from the Control branch, make the following selections:
Press the
VF_Thresh_Update.
Select Edit.
In the following example, the RSL High threshold is changed from 09 (–dBm) to 10. This example
demonstrates VF threshold editing and saving. With the exception of Signal Quality, all VF
thresholds may be modified in this manner. Signal Quality uses a menu selection with possible
values of Excelent (Excellent), Good, Fair, Poor, or No Signal. Editing and saving a VF threshold
is similar to editing and saving a configuration option. (For another example of editing and saving,
refer to the Editing and Saving a Configuration Option section in Chapter 4.)
3-42
RemClone Status
Bank1:xxxx/yyyy
F1
F2
F3
Control:
<
VF_Thresh_Update
F1
F2
F3
key until VF_Thresh_Update appears. Press any function key to select
VF Thresholds
Edit
Save
Reset
F3
F1
F2
November 1996
3910-A2-GN32-30