Paradyne COMSPHERE 3910 Installation And Operation Manual page 153

3900 series point-to-point/multipoint modems
Hide thumbs Also See for COMSPHERE 3910:
Table of Contents

Advertisement

COMSPHERE 3900 Series Modems
NMS_Call_Msgs: CallCnct&Prg
Nxt CallCnct&Prg Disable CallCnctOnly CallProgOnly
NMS Call Messages. Determines if the modem status and/or call summary information is sent to the NMS.
The modem can itemize status, such as CallProgress messages, or it can report a summary of activity, such
as Call Connect messages, to the NMS.
Call Connect & Progress
Enables both Call Connect and Call Progress information to be transmitted to the NMS.
Disable
Modem status and call summary information is not sent to the NMS.
Call Connect Only
The modem accumulates call statistics over a period of time and then transmits a summary of these
statistics to the NMS. The NMS uses this data to produce utilization reports.
Call Progress Only
The modem transmits detailed modem status information to the NMS. These messages include any
events that can display on the LCD.
NOTE: For 6800 Series NMS applications, Disable must be selected.
The AT commands are S-Register S66= n where n is 0 for Call Connect & Progress, 1 for Disable, 2 for Call
Connect Only, and 3 for Call Progress Only.
NetworkPosition: Tributary
End Tributary Control
Network Position Identification. Each modem must be identified either as a control modem or a tributary
modem.
NOTE: Changes to this configuration option will cause the modem to reset.
NOTE: This configuration option is only applicable for leased-line network management applications.
For the Model 3910, Tributary is the factory default.
For the Model 3911, Control is the factory default.
The AT command for Tributary is S74=0.
The AT command for Control is S74=1.
NetMngmtAddress: 256
Nxt
256
This configuration option is not available in point-to-point tributaries.
Network Management Address. Determines the address used when accessing a modem from the NMS or
when using DCP functions that require network management addresses. Within a network link, a control
modem can communicate with a tributary modem by using the tributary modem's network management
address. Each tributary modem must have a different network management address.
NOTE: Changes to this configuration option will cause the modem to reset.
NOTE: A point-to-point tributary is always Address 1.
Address values range from 001 to 256.
The AT command is S-Register S75= n , where n is a value from 0 to 255 (001 to 256).
4-50
Table 4-8
(3 of 4)
Miscellaneous Configuration Options
November 1996
3910-A2-GN32-30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3911

Table of Contents