Remote Branch

The Remote branch of the Top-Level menu allows you to control the remote modem's DCP using
the local modem's DCP. This function allows you to change configuration options and control test
functions in a remote modem. Any changes made to configuration options while using the Remote
branch are not saved until you exit the Remote branch. This function is only available when using
either V.32 terbo, V.32bis, V.32, TMp, V.33, or V.29 modulation schemes.
Status
Configure
The following conditions must be met before using the Remote branch:
Remote DCP access is accomplished using either the primary or secondary channel (if available)
of the VF line. Using the primary channel gives a much faster response time due to the higher data
rate, but it also interrupts data flow because primary data is stopped when Remote mode is active.
Once Remote mode is terminated, the primary channel is automatically made available for data
transmission.
Unlike primary channel communications, the secondary channel operates at a slower data rate and
does not interrupt data flow. (V.32 terbo, V.32bis, V.32, and TMp are the only modulations
available for the secondary channel.)
3910-A2-GN32-30
Plist
Control
Test
A connection using either leased lines or the dial network must be established.
The Access from the Remote configuration option must be enabled in the remote modem.
In point-to-point networks, the Remote Access Password configuration option must be the
same for both the local and remote modems. In multipoint networks the remote access
password must be entered at the appropriate prompt.
For multipoint control modems, the network management address of the tributary modem
must be entered at the appropriate prompt.
November 1996
"Status"
SubHS
Call_Setup
DCP Operation
Tlk/Data
Security
Remote
Choose Address
(TMp Control only)
Choose Password