Configuration Options; Cables - Paradyne COMSPHERE 3910 Installation And Operation Manual

3900 series point-to-point/multipoint modems
Hide thumbs Also See for COMSPHERE 3910:
Table of Contents

Advertisement

Multipoint
Figure G-2 shows a sample configuration for multipoint applications.
TMp control modems can accept mixed inbound rates from tributary modems. For example, one
inbound link may be configured for 14.4 kbps while another link experiencing line impairments
may be configured for 9.6 kbps. The following control/tributary rate combinations are allowed:
control at 19.2 kbps, tributaries at 14.4 or 9.6 kbps; control at 14.4 kbps, tributaries at 14.4 or 9.6
kbps; control at 9.6 kbps, tributaries at 9.6 or 7.2 kbps; control at 7.2 kbps, tributaries at 7.2 or 4.8
kbps; control at 4.8 kbps, tributaries at 4.8 or 2.4 kbps; control at 2.4 kbps, tributaries at 2.4 kbps.
Tributary rates will never exceed control rates. If tributary and control rates are equal, reducing the
control rate will automatically reduce the tributary rate.
DTE
(Sync)
Cable 1

Configuration Options

3910 A
3910 B
3910 C

Cables

Cable 1
Cable 2
3910-A2-GN32-30
19200(TMp)
TX
Leased
A
3910
Cable 2
Figure G-2. Sample Configuration — Multipoint
Use TMp (Control) default configuration options.
Use TMp (Trib) default configuration options.
Use TMp (Trib) default configuration options.
Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug)
connector at one end to attach to the modem. Attach this to the connector labeled
DTE1.
Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is
supplied with the modem). Attach this to the connector labeled LEASED.
November 1996
14400(TMp)
TX
B
3910
Cable 2
Cable 1
14400(TMp)
TX
C
3910
Cable 2
Cable 1
Sample Configuration
DTE
(Sync)
DTE
(Sync)
G-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3911