Function Block Fb1; Job - Siemens SIMATIC VS120 Operating Instructions Manual

Image processing systems vision sensor
Table of Contents

Advertisement

Process interfacing over an automation system (PLC, PC)

10.5 Function block FB1

10.5
Function block FB1
10.5
To simplify operation of the functions of SIMATIC VS120 Vision Sensor, there is a function
block FB1 for IO operations.
In addition to the SIMATIC S7 system mechanisms for the integration of SIMATIC VS120
Vision Sensor in a PROFIBUS DP or PROFINET IO environment, FB1 simplifies the
software integration in control programs.
10.5.1

Job

Tasks of the function block FB1
• Selecting a model or model set
• Reading the result data and entering it in DB10
• Operating the control and status interface (triggers, results bits,...)
• Transferring the delay time of the trigger
• Outputting error messages
Figure 10-5
Tasks of data block DB10
DB10 is designed for the structured entry/storage of data from a main ROI and a maximum
of 16 sub-ROIs. The number of sub-ROIs is set in Connections - Output tab in adjustment
support
10-16
(DB10 is included in the documentation package)
Function block FB1
Vision Sensor SIMATIC VS120
Operating Instructions, Edition 02/2006, A5E00757507-01

Advertisement