Alarm, error and system messages
11.2 Error messages and error handling
No.
10
11
11-4
Message on
PROFIBUS
the LCD
DP bit no.
display
starting at
diagnostic
byte 0
TCP/RS232
14
Communic.
Archive
14
Communic.
PROFINET
Description
IO
Value
W#16#500E
Connection error
in communication
over a TCP
connection or
when using an
Ethernet RS-232
converter:
There is no TCP
connection or the
data transmission
cannot be
completed within
the set time.
W#16#500E
Error in
communication
over the archiving
connection: There
is no TCP
connection, the
server does not
respond within the
set time limit or
violates the
archiving protocol.
Operating Instructions, Edition 02/2006, A5E00757507-01
Remedies
Make sure that the
connected TCP server or
Ethernet RS-232 converter
is correctly configured and
ready to receive.
Depending on the
connected Ethernet RS-
232 converter, it can take
up to 20 s before changes
to the RS-232 settings or
parameter changes for the
trigger source or the output
of the result string to
"TCP/RS232" take effect.
During this time, the first
trigger of a processing
cycle should not occur nor
should that be a change to
RUN.
Check the connection to
the server.
Make sure that the data is
processed by the server in
an adequately short time
and that the protocol is
maintained.
Vision Sensor SIMATIC VS120