Siemens SIMATIC VS120 Operating Instructions Manual page 86

Image processing systems vision sensor
Table of Contents

Advertisement

Operation
9.2 Working with the processing unit
Step
6
7
8
9
10
11
12
9-12
Display
Meaning
M 02 Trig.
M 02 Trig.
Too Fast
Too Fast
=0
=0.000%
6/14 ←
OK
6/14 ←
Since the beginning of the statistical analysis for the model 02, the
M 02 Qual.
lowest quality value was 85% and the highest 99%.
min=85%
max=99%
7/14
OK
Since the beginning of the statistical analysis for model 02, the
M 02 X−Pos
lowest x coordinate of the target rectangle was -222 and the
min=−222
highest 233.
max=233
8/14
OK
Since the beginning of the statistical analysis for model 02, the
M 02 Y−Pos
lowest y coordinate of the target rectangle was -14 and the highest
min=−14
89.
max=89
9/14
OK
Since the beginning of the statistical analysis for the model 02, the
M 02 Angle
lowest roll angel was -120.1° and the highest 179.3°.
min=−120.1
max=179.3
10/14
OK
For model 02, the midpoint of the target rectangle has the following
M 02 ROI Pos
coordinates: x=-2, y=4
cx=−2
cy=4
11/14
OK
For model 02, the target rectangle has the following dimensions:
M 02 ROI Dim
Width=101, Height=102
width=101
height=102
12/14
OK
Absolute and relative number of image
processing procedures during which the
next trigger signal came too fast
OK
.
Operating Instructions, Edition 02/2006, A5E00757507-01
Vision Sensor SIMATIC VS120