Siemens SIMATIC VS120 Operating Instructions Manual page 78

Image processing systems vision sensor
Table of Contents

Advertisement

Operation
9.2 Working with the processing unit
Figure 9-2
"Connect" parameter menu
Parameters
Path
Port
Pulsetime
Ports>DI/DO
Address
Ports>DP
(not active if IP
Mode = PNIO)
Timeout
Ports>DP
(not active if IP
Mode = PNIO)
Pulsetime
Ports>DP
(not active if IP
Mode = PNIO)
DevName
Ports>PNIO
(only active if IP
Mode = PNIO)
Timeout
Ports>PNIO
(only active if IP
Mode = PNIO)
Pulsetime
Ports>PNIO
(only active if IP
Mode = PNIO)
IP mode
Ports>Ethernet
9-4
Structure of the Connect menu continued
Possible Values
5 to 999
1 to 125
100 to 2000
5 to 999
String (0 to 9, A to
Z, a to z, ".", "-").
The string must
match the
conventions of the
domain name
system.
100 to 2000
5 to 999
Default
Meaning
30
Pulse time of the digital outputs OK,
N_OK in ms on the DI/DO interface
7
Address on PROFIBUS DP
500
Handshake monitoring time in ms
30
Pulse time of the digital outputs OK,
N_OK in ms when output is via
PROFIBUS DP
VS120
Name of the device on PROFINET
Note: PROFINET is not case sensitive
500
Handshake monitoring time in ms
30
Pulse time of the digital outputs OK,
N_OK in ms when output is via
PROFINET IO
Note: For the pulse time, select a higher
value than for the update time of the
PROFINET IO system in HW Config.
Assignment of the IP address to the
processing unit in the network.
Operating Instructions, Edition 02/2006, A5E00757507-01
Vision Sensor SIMATIC VS120