Siemens SIMATIC VS120 Operating Instructions Manual page 85

Image processing systems vision sensor
Table of Contents

Advertisement

Sequence of tasks in the RUN menu for a model based on the example of a model with number 2:
Step
1
2
Step
1
2
3
4
5
Vision Sensor SIMATIC VS120
Operating Instructions, Edition 02/2006, A5E00757507-01
Display
Activity
Select "Info" on the processing unit at the "RUN" menu level using
STOP
the ⇓ and ⇑ arrow keys and press "OK". This opens the first Into
Q−Limit
screen.
> Info
ESC
↓↑
OK
Using the arrow buttons ⇓ and ⇑, you can display further Info
M 02
OK
screens. Pressing "OK" returns you to the highest hierarchy level
=3226
of the "RUN" menu.
=99.907%
1/14
OK
Display
Meaning
Since the last processing start, the pattern search for model 2 was
M 02
OK
performed successfully in 3226 image recordings. This
=3226
corresponds to 99.907% of all images processed since processing
=99.907%
last started.
1/14
OK
6 examinations were below the warning limit since the last start of
M 02 WARN
processing. This corresponds to 0.194 % of all images processed
=6
since processing last started.
=0.194%
2/14
OK
3 specimens could not be identified as model 2 since processing
M 02 N_OK
started. This corresponds to 0.093 % of all images processed
=3
since processing last started.
=0.093%
3/14
OK
The required processing time (cycle time) for the specimen
M 02 Curr.
currently under examination is 300 ms.
Cycletime
=300ms
4/14
OK
Since the beginning of the statistical analysis for model 02, the
M 02 Cycle
shortest evaluation time was 120 ms and the longest 276 ms.
min=120ms
max=276ms
5/14
OK
9.2 Working with the processing unit
Operation
9-11

Advertisement

Table of Contents
loading