11.1 Integration in SIMATIC S7-1200
11.1.3

Calling of function block

This description is based on use of the WP241PR block with data record communication and
the following data:
● Start address SIWAREX WP241: 68 (see → Creating the hardware configuration
(Page 154))
● HW ID SIWAREX WP241: 271 (see → Creating the hardware configuration (Page 154))
● Instance data block number of SIWAREX WP241 function block: DB241
The function block can be integrated at the desired position in the user program using drag
and drop. Calling of the FB must be carried out cyclically in the control program.
Figure 11-5
Function block parameter
ADDR
HW_ID
DB_NO
LIFEBIT
The generated instance DB (DB241 in this case) contains all data records of the WP241 as
well as all parameters required to exchange data between CPU and weighing module.
A separate FB call must be made in the user program for each weighing module. In this
manner, each scale receives its own instance DB which provides the respective scale
parameters. The input and output parameters of the FB must be matched to the respective
WP241 for each call.
156
Calling of WP241PR block in user program
Description
Start address WP241 (see → Creating the
hardware configuration (Page 154))
HW ID WP241 (see → Creating the hardware
configuration (Page 154))
Number of FB-internal instance DB
Optional status bit can be used to monitor
communication
Manual, 04/2014, A5E33713528A
SIWAREX WP241