11.2 Error messages and error handling
No.
3
4
5
6
11-2
Message on
PROFIBUS
the LCD
DP bit no.
display
starting at
diagnostic
byte 0
Model corrupt
5
Internal file
5
error
TCP/RS232
7
Trm. Error
Archive
7
Trm. Error
PROFINET
Description
IO
Value
W#16# 5005 The model could
not be recreated.
W#16# 5005 An error occurred
when saving to
the read-only
memory.
W#16# 5007 The send buffer is
full because the
data cannot be
sent in an
adequately short
time,
W#16# 5007 The send buffer is
full because the
data cannot be
sent in an
adequately short
time or the server
does not confirm
receipt of the data
in good time
Operating Instructions, Edition 02/2006, A5E00757507-01
Remedies
Run the training again.
Contact Customer Support
if this error occurs often.
Reduce the trigger
frequency or process the
results more quickly on the
server. A high load on the
network to which the
processing unit is
connected can also block
the transfer of the data. If
necessary, check the
network connection.
Reduce the trigger
frequency or reduce the
amount of diagnostic data
to be archived. Process
the results on the server
faster. A high load on the
network to which the
processing unit is
connected can also block
the transfer of the data. If
necessary, check the
network connection.