Siemens SIMATIC VS120 Operating Instructions Manual page 82

Image processing systems vision sensor
Table of Contents

Advertisement

Operation
9.2 Working with the processing unit
Parameters
Path
Output
Encoding
Output
Byte order
Output
(only if Encoding =
Binary)
Format (only if
Output
Encoding = ASCII)
Position
Output
Sub-ROIs
Output
9-8
Possible Values
Default
Binary
Binary
ASCII
S7
S7
Intel
CSV
CSV
Fix
Absolute
Absolute
Trained
0 ... 16
16
Meaning
The results for the main ROI and sub-
ROI are sent as binary data or ASCII
strings through the output interface set
in Integrate>Output
Specifies the byte sequence for data
types greater than 8 bits.
S7 format:
Big endian (for a data type greater than
8 bits, the low byte is at the most
significant byte position.)
Intel format:
Little endian (for a data type greater than
8 bits, the low byte is at the least
significant byte position.)
This is where you enter the format for
your output data.
CSV: Send in CSV format
Fix: Send individual results with a
fixed length of 12 characters
This is where you specify the reference
point.
Absolute:
The position of all ROIs are output as
absolute in relation to the image center
Trained::
The position of the main ROI is output
relative to its position at training based
on the image center.
The position of the sub-ROI is output
relative to its position at training based
on the center of the main ROI.
Note:
This parameter only relates to the
results to be transferred and not to the
displayed results from the screen and
applets.
This is where you enter the number of
sub-ROIs that you wish to transfer.
Vision Sensor SIMATIC VS120
Operating Instructions, Edition 02/2006, A5E00757507-01

Advertisement