Siemens SIMATIC VS120 Operating Instructions Manual page 81

Image processing systems vision sensor
Table of Contents

Advertisement

Parameters
Path
Integrate
Delay
Integrate>
Trigger
DelaySrc
Integrate>
Trigger
DP(S7) or
Integrate>
PNIO(S7)
Trigger>
(only if Control DP
DelaySrc
or PNIO)
DP or PNIO
Integrate>
(only if Control DP
Trigger>
or PNIO)
DelaySrc
Manual
Integrate>
Trigger>
DelaySrc
Output
Integrate
OK/N_OK
Integrate
Control
Integrate
DiagImage
Integrate
DiagReport
Integrate
Vision Sensor SIMATIC VS120
Operating Instructions, Edition 02/2006, A5E00757507-01
Possible Values
Default
0 to 9999 ms
0 ms
for normal
triggers
0 to 9999950
µs with a fast
trigger or if
DelaySrc is not
manual
Manual
Manual
DP(S7) or
PNIO(S7)
DP or PNIO
-
-
-
-
-
-
DP or PNIO
None
TCP/RS-232
None
DP or PNIO
DI/DO
DI/DO
None
DP or PNIO
DI/DO
DI/DO
None
None
Archives
None
None
Archives
9.2 Working with the processing unit
Meaning
This is where you enter the time by
which the trigger signal should be
delayed.
Note:
If DelaySrc is not manual, the values
received via DP / PNIO are displayed
here. They cannot be edited.
Note:
DP(S7) corresponds to
PROFIBUS DP with S7 format (big
endian format)
DP corresponds to PROFIBUS DP
with Intel format (little endian format)
The trigger delay is received through the
DP(S7) or PNIO(S7) user data interface
from the controller in S7 format.
The trigger delay is received by the
controller over the user data interface
DP or PNIO in Intel format.
Editable values are used in the delay.
This is where you enter the interface via
which the results are output.
Here, you specify the interface over
which the result bits OK and N_OK are
output.
Here you specify the port for the DISA,
SEL0, SEL1, SEL2, SEL3, RES, IN_OP,
TRD, RDY signals.
This is where you specify if the
diagnostic images should be sent to a
server.
This is where you specify if the
diagnostic reports should be sent to a
server.
Operation
9-7