6.1

Installing the SIMATIC VS120 processing unit

6.1
1. For the location of the fixing holes, refer to the
2. Mount the processing unit so that it is easily accessible for the operator
6.2

Installing the sensor head with LED ring flash

6.2
Notice
Aligning the optical axis
Align the optical axis of the sensor head vertical to the direction in which the object is
conveyed. Otherwise the image of the object will be distorted. The evaluation will be
inaccurate.
If the objects always pass the sensor head in the same position, the angle of the mid axis of
the objects to the vertical can be up to 45°.
Notice
Distance D between sensor and object
The ideal distance D between sensor and object depends on the type of sensor head. With
sensor heads with the order numbers (MLFB) below, the recommended distance D is as
follows:
• 6GF2 002-8DA01: 100 mm
• 6GF2 002-8EA01: 90 mm