Siemens SIMATIC VS120 Operating Instructions Manual page 165

Image processing systems vision sensor
Table of Contents

Advertisement

Diagnostics for PROFINET IO
Receive alarm with SFB54 "RALRM"
SFB54 "RALRM" returns the following diagnostic information in the TINFO parameter
(task information) for PROFINET IO:
Byte
0 to 19
20 to 21
22
23
24
25
26 to 27
28 to 29
30 to 31
The SFB 54 "RALRM" returns the following diagnostic information in the AINFO parameter
(alarm status information) for PROFINET IO:
Note
Only bytes 0 to 25 of the AINFO parameter are written for alarms exiting state (see also the
meaning of bytes 2 and 3 of AINFO).
Vision Sensor SIMATIC VS120
Operating Instructions, Edition 02/2006, A5E00757507-01
Value
See OB description
Depending on configuration
B#16#08
B#16#00
B#16#00 / B#16#01
B#16#01 / B#16#00
W#16#0B01
W#16#002A
W#16# 0001
Alarm, error and system messages
11.4 Slave diagnostics or /O device diagnostics
Meaning
Start information of the OB in which SFB 54 is called
Address:
Bit 0 to 10: Station number (acc. to configuration)
Bit 11 to 14: IO system ID (acc. to configuration)
Bit 15: 1
Bit 0 to 3: Slave type 1000 = PNIO
Bit 4 to 7: Profile type: 0000
Bit 0 to 3: Alarm info type: 0000
Bit 4 to 7: Structure version: 0000
Flags of the PNIO controller interface:
Bit 0 = 0: Alarm from integrated interface module
Bit 0 = 1: Alarm from external interface module
Bits 1 through 7: In each case 0
Flags of the PNIO controller interface:
Bit 0 = 1 for alarm entering state
Bit 0 = 0 for alarm exiting state
Bits 1 through 7: In each case 0
PNIO device identification number (fixed)
Manufacturer ID (fixed)
Identification number of the instance