Mechanical Environmental Conditions for Operation
SIMATIC VS120 is designed for fixed installation in an environment protected from the weather and
meets the conditions for use complying with DIN IEC 60721-3-3:
Mechanical environmental conditions, sine-shaped oscillations
Frequency range in Hz
10 ≤ f < 58
58 ≤ f < 500
Test for mechanical environmental conditions
Test for / Test standard
Vibrations
Oscillation test complying
with IEC 60068-2-6
(sine)
Test for / Test standard
Shock
Ambient climatic conditions for operation
Ambient conditions
Temperature
Temperature change
Relative humidity
Atmospheric pressure
Contaminant
concentration
Vision Sensor SIMATIC VS120
Operating Instructions, Edition 02/2006, A5E00757507-01
Class 3M3 (mechanical requirements);
Class 3K3 (climatic environmental conditions);
Test values
0.075 mm amplitude
1 g constant acceleration
Comments
Comments
Shock test
complying with
IEC 60068-2-29
Shock test
Sensor head, illumination:
complying with
IEC 60068-2-27
Permitted range
0 to +50° C
Max. 10 °C/h
max. 95 % at +25 °C
1080 to 795 hPa, corresponds to
a height of 1000 to 2000 m
Vibration type: Frequency cycles with a rate of change of 1
octave/minute.
10 Hz ≤ f < 58 Hz, constant amplitude 0.075 mm
58 Hz ≤ f < 500 Hz, constant acceleration 1 g
10 Hz ≤ f ≤ 55 Hz, amplitude 1 mm (only sensor head and lighting
unit)
Vibration duration: 10 frequency cycles per axis in each of
the 3 perpendicular axes.
Type of shock: Half-sine
Strength of the shock:
Processing unit 10 g peak value / 16 ms duration
Sensor head, illumination: 10 g peak value / 16 ms duration
Direction of shock: 100 shocks in each of the 3 perpendicular axes
70 g peak value / 6 ms duration 3 times in each direction
30 g peak value / 11 ms duration 3 times in each direction
SO
: < 0.5 ppm; RH < 60 %,
2
no condensation
H2S: < 0.1 ppm;
RH < 60 %, no condensation
Technical data
12.1 General technical specifications
Comments
No condensation, corresponds to
relative humidity degree 2 to
IEC 61131-2.
Check: 10 ppm; 4 days
Check: 1 ppm; 4 days
12-3