Part 3/3: Version
This is where you specify the format for outputting the results through the interface set in the
Connections - Output
Figure 9-12
9.3.4
Train
When a model is transferred, the SIMATIC VS120 Vision Sensor learns the significant
characteristics (edges) of the model's main ROIs and Sub-ROIs for subsequent processing
of the specimen.
After selecting Training, five tabs appear:
• Selection
• ROI
• Edges
• Test
• Save
The easiest way to train a model is to work through the tabs one after the other. You can use
the
specific tabs. If tabs are skipped, the defaults values will be set.
Vision Sensor SIMATIC VS120
Operating Instructions, Edition 02/2006, A5E00757507-01
selection menu of the "Connections - Integration tab".
Connections - Output tab
Next
Back
and
buttons to navigate between the tabs. You can, however, also select
Operation
9.3 Working with setup support
9-27