Field Service Ver. 2.5 Jul. 2006
MODE
Bit:
831
Bit
Feature
7
NSF sending
6
NSS sending
5
Send DIS (digital identifica-
2
tion signal) in 4 Bytes
Confidential – for internal use only, do not distribute
Factory setting bit
7 6 5 4
3 2 1 0
1 1 0 0
0 0 0 0
Logic
0
Not
Allowed
allowed
Not
Allowed
allowed
Not
Restrict
restrict
DIS to 4
DIS to 4
bytes
bytes
HEX: C0
Description
1
Set whether or not to allow to send
NSF (Non-standard function) signal. If
setting Not allowed, make communica-
tion only with T30 standard protocol
signal.
Set whether or not to allow to send
NSS (Non-standard function setting)
signal. If setting Not allowed, make
communication only with T30 standard
protocol signal.
When sending DIS, set whether to
restrict to 4 bytes.