18. Malfunction code
18.3.14

C3451: Fusing Warm-Up Failure (Main)

18.3.15

C3452: Fusing Warm-Up Failure (Sub)

18.3.16

C3751: High Fuser Temperature Failure (Main)

18.3.17

C3752: High Fuser Temperature Failure (Sub)

Fusing Roller Heater Lamp (H1)
Fusing Roller Sub Heater Lamp (H2)
Fusing Roller Thermistor (TH1)
Fusing Roller Sub Thermistor (TH2)
Step
Check that the H1 comes on when the Main Power
1
Switch is set to ON, and correct or replace as nec-
essary.
Check that the H2 comes on when the Main Power
2
Switch is set to ON, and correct or replace as nec-
essary.
Check the installation of the TH1 and the TH2, and
3
correct or clean as necessary.
Check the operation of the TH1.
Remove CN80 (4P), and then check that the resis-
4
tance across CN80-2 and -3 on the Thermistor is
infinity.
Check the operation of the TH2.
Remove CN81 (4P), and then check that the resis-
5
tance across CN81-2 and -3 on the Thermistor is
infinity.
Check the continuity of the H1.
6
Correct or replace as necessary.
Check the continuity of the H2.
7
Correct or replace as necessary.
8
Change PU1
9
Change PWB-A
248
Relevant Electrical Parts
Action
Confidential – for internal use only, do not distribute
Field Service Ver. 2.5 Jul. 2006
Mechanical Control Board (PWB-A)
Power Supply Unit (PU1)