Scanner System: White Streaks Or Bands - Konica Minolta bizhub 200 Service Manual

Hide thumbs Also See for bizhub 200:
Table of Contents

Advertisement

20. Image quality problem
20.3.6

Scanner System: White streaks or bands

A. Typical Faulty Images
B. Troubleshooting Procedure
Step
Section
1
Original
2
Original Cover
3
4
Shading Sheet
5
Mirrors/Lens/
Original Glass/
Reflectors
6
Exposure Lamp
7
BCRS Board
8
264
4036fs4021c0
Check Item
Original is damaged or dirty.
Original Pad is dirty.
Original Cover does not lie flat.
Shading sheet is dirty.
Mirrors, lens, Original Glass and/or
reflectors are dirty.
Exposure Lamp is dirty.
The problem has been eliminated after
performing step 6.
The white lines or bands are blurry or
opaque.
Confidential – for internal use only, do not distribute
Field Service Ver. 2.5 Jul. 2006
4036fs4022c0
Result
Action
YES
Change original.
YES
Clean.
YES
Replace Original Cover if
it is deformed or the
hinges are broken.
YES
Clean.
YES
Clean.
YES
Clean.
Change Exposure Lamp.
NO
Change the Jumper
Switch Setting on the
BCRS Board.
P.223
YES
Change Exposure Unit.
Change CCD Unit.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 250Bizhub 350