Misfeed At Duplex Unit Take-Up Section - Konica Minolta bizhub 200 Service Manual

Hide thumbs Also See for bizhub 200:
Table of Contents

Advertisement

Field Service Ver. 2.5 Jul. 2006
17.3.6

Misfeed at Duplex Unit take-up section

A. Detection Timing
Type
Detection of misfeed at
Duplex Unit take-up
section
Detection of paper left in
Duplex Unit take-up
section
B. Action
Synchronizing Roller Sensor (PC1)
Duplex Unit Lower Transport Sensor (PC25)
Step
1
Initial check items
2
PC1 I/O check
3
PC25 I/O check
4
Change PWB-A
Confidential – for internal use only, do not distribute
The Synchronizing Roller Sensor (PC1) is not blocked even after the set
period of time has elapsed after the Duplex Unit Lower Transport Sensor
(PC25) has been blocked by the paper.
The Duplex Unit Lower Transport Sensor (PC25) is blocked when the Main
Power Switch is set to ON, a door or cover is opened and closed, or a mis-
feed or malfunction is reset.
Relevant Electrical Parts
Mechanical Control Board (PWB-A)
Action
17. Jam Display
Description
WIRING DIAGRAM
Control Signal
-
PWB-A PJ11A-5 (ON)
PWB-A PJ20A-8 (ON)
-
Location
(Electrical
Component)
-
M-8
M-16
-
233

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 250Bizhub 350

Table of Contents