3-2 Material Mode
To load a material in a currently unused recorder port
To switch the material in the material list
3-8 (E)
Chapter 3 Operating Modes
When the recorder port currently the subject of operation is unused, you can
load material to it by using the EDIT button and function key B1 (Load).
1
With the MULTI CONTROL knob, move the cursor to the material that
you want to assign.
2
Press function key B1 (Load) while pressing the EDIT button.
• The LOAD operation begins, and the material selected in step 1 is
assigned to the port currently the subject of operation. At the same time,
the system cues up the end of the material.
• If the power goes off during loop recording, you can reassign material
and resume recording.
For details about function keys, see Section 3-2-3 "Key Assignments in
Material Mode" (page 3-4).
Notes
• It only possible to load loop recorded material in this way. It is not possible
to load material recorded normally.
• It is not possible to load a material this way when using the MAV-555SS in
SS mode.
• It is not possible to load the following types of material. If you attempt to
load one of these types of material, when you press the EDIT button the
"Load" caption on the B1 (Load) key is dimmed, indicating that the key is not
valid.
- SS material (recorded in SS mode)
- Material loaded to a different port
- Material for which the Protect attribute is "Protected"
- Material for which the Category attribute is "Edited"
• The settings of loaded material comply with CP Setup mode items 0001:
Record Allocate Length and 0002 Record Loading Option. Because of these
settings, if a material is long, loading is possible, but it is not possible to
record from the end of the material.
If you want to record from the end of the material, modify the allocated
record length in CP Setup mode item 0001: Record Allocate Length.
• If you stop loop recording when System Remain has reached zero (0), it is
not possible to reload the same material to an unused recorder port because
System Remain is zero.
Material assigned to the port that is currently the subject of operation can be
switched in the material list using the F.FWD or REW buttons. To switch the
material, set item 0007 Material Index Jump in CP Setup mode to an item
other than Disable.
For settings, see Section 3-6, "CP Setup Mode" (page 3-34).