Keypad Configuration Mode; Keypad Installation; Configuring The Keypads - NAPCO GEMINI GEM-P3200 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEMINI GEM-P3200:
Table of Contents

Advertisement

WI818G 10/05

KEYPAD CONFIGURATION MODE

This section will focus on configuring the GEM-RP1CAe2/GEM-K1CA Keypads. If there is more than one keypad in the system, only
Keypad No. 1 may be used for programming.

KEYPAD INSTALLATION

Two types of keypads may be used with the GEM-P3200: the GEM-RP1CAe2/GEM-K1CA. Each must be assigned an address
number (1–7) and each requires its own configuration procedure (see CONFIGURING THE KEYPADS, which follows, and DIRECT
ADDRESS KEYPAD AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-area Commercial Burglary
installation.
GEM-RP1CAe2/GEM-K1CA - is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones and a
PGM output. The GEM-RP1CAe2 or GEM-K1CA is recommended for use as Keypad #1. See "Important Note" on page 2
for more information regarding the various buttons on the GEM-RP1CAe2/GEM-K1CA keypads.

CONFIGURING THE KEYPADS

A total of up to 7 keypads may be connected to the panel.
Configuring the GEM-RP1CAe2/GEM-K1CA Keypad
Each GEM-RP1CAe2/GEM-K1CA keypad must be configured for (a) keypad tactile beep; (b) entry sounder; (c) keypad address; (d)
compatibility number; (e) EZM address; and (f) zone response.
To enter the Keypad Configuration Mode:
1. Move jumper JP1 (located in the center of the control panel board) from Pins 1-2 (top two) to Pins 2-3 (bottom
two). NOTE: See Wiring Diagram on page 68.
2. After about 15 seconds, the display will read "XX OUT OF SYSTEM", where XX indicates the keypad address.
3. Press
11123 R
all keypads).
Keypad Beep
Entry Sounder
Keypad Address
L
NAPCO Security Systems
and proceed as follows. (Repeat the following procedure for
Keypad Tactile Beep
Upon entering the Keypad Configuration Mode, "KEYPAD BEEP ON" will be displayed,
indicating that the tactile beep, which sounds when any button is pressed, is on.
ON
To turn off the tactile beep, press the
tile beep on and off). Press
Entry Sounder
To turn off the keypad entry sounder during entry time, press
ON
will toggle the entry sounder on and off). Press
C
to exit.
Keypad Address
If more than one keypad is installed, each must be assigned a unique keypad
01
address (that is, no two keypads may be numbered alike):
Keypads must be numbered consecutively (missing numbers are not permitted)
Only Keypad No. 1 may be used for programming.
To assign the keypad number, proceed as follows:
1. Enter the assigned keypad number 01–07, then press
number will be acknowledged by a short beep; an invalid number will be re-
jected by a long beep.
2. Press
R
to continue or press
U
U
button (the
to continue or press
R
R
C
to exit.
X
GEM-P3200 Programming Instructions
Page 55
GEMINI
# OF ZONES IN AREA
SYSTEM ARMED
# OF ZONES IN AREA 1
ENTER # ZONES XX
01/01/97 12:00AM
ENTER # ZONES X X
NEXT/YES
A
1 2
3
E
D
PRIOR/NO
B
4
5 6
F
AREA
C
7 8 9 0
G
COMPUTERIZED SECURITY SYSTEM
R
NORMAL
KEYPAD
CONFIGURE
button will toggle the tac-
to exit.
C
U
U
(the
button
to continue or press
U
to save. A valid

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gem-p3200