E n t e r u s e r c o d e
0 0 1 1 2 3
- E 3 -
User#
User Code
Press the
button to set the cursor to the User Code. Use the number buttons
R
a code from 3 to 6 digits. Enter up to 6 digits in the first six boxes from left to right for each user code. Valid entries
are: 0-9. Note: Press the
an "Ambush Code" (Address 0495) is entered, do not program the first two digits of ANY User Code as the same
digits entered for the "Ambush Code".
If the programmed code is less than 6 digits, press the
Refer to the tables below for the available User Option and User Level data entries. Enter the user options data in
the left digit. Enter the level data (with arming options, if any, added) in the right digit. Note: For entries greater than
9, press the
G1
For Keypad Access Control, press the
below, use the number buttons to enter the data for Keypad 1–4 in the right digit; and the data for Keypad 5–7 data in
the left digit. (Press the
0
Example: Enter a code of "123456" as
"123456" (from left to right).
USER OPTIONS
DATA
BLOCKED
USER
BYPASS
ENTRIES
VIEW
PROGRAM
blank (•)
DISABLED
1
Y
2
Y
3
Y
Y
4
Y
5
Y
Y
6
Y
Y
7
Y
Y
Y
8
9
Y
0
Y
B
Y
Y
C
Y
D
Y
Y
E
Y
Y
F
Y
Y
Y
Note: "Y" indicates option is enabled.
X
GEM-P3200 Programming Instructions
Enter User Codes (Press the
Enter up to 48 User Codes with User Options, Authority Level and Access
Control Options (if necessary) for each code. Refer to the tables below and on
the next page for available data entries for User Options, Authority Level and
Access Control Options. Note: All 48 Users must be assigned to areas in "User
Area Options" (Address 2455-2502) in Direct Address Programming. By de-
fault, only User 1 is enabled in Area 1 and Area 2. Users 2 - 8 are enabled in
Area 1 and users 9 - 16 are enabled in Area 2.
button for a zero. No blank spaces in between; leave blank (•) any trailing boxes. If
0
buttons through the
G5
button once again to program applicable keypads. Refer to the tables
R
buttons for blank).
USER CODE
(UP TO 6 DIGITS)
DATA
AUTHORITY
ENTRIES
LEVEL
OVERVIEW
blank (•)
NONE
1
LEVEL 1
2
LEVEL 2
3
LEVEL 3
4
NONE
5
LEVEL 1
6
LEVEL 2
7
LEVEL 3
8
NONE
Y
9
LEVEL 1
Y
0
LEVEL 2
Y
B
LEVEL 3
Y
C*
NONE
Y
D*
LEVEL 1
Y
E*
LEVEL 2
Y
F*
LEVEL 3
Y
*Note: These entries are only
available when address 3905
option 8 is enabled.
button to set cursor.)
R
button to set the cursor to the OPTION/LEVEL.
R
buttons for B through F, respectively.
USER OPTIONS
USER
USER
ACCESS CONTROL
OPTION
LEVEL
KEYPADS
CODE
ACCESS CONTROL KEYPADS
TYPE
DATA
K.P. 5 K.P. 6 K.P. 7
ENTRIES
ARM/DISARM
ARM/DISARM
blank (•)
NONE
ARM/DISARM
1
Y
ARM/DISARM
2
Y
ARM ONLY
3
Y
Y
ARM ONLY
4
ARM ONLY
5
Y
ARM ONLY
6
Y
SERVICE
7
Y
Y
SERVICE
8
SERVICE
9
Y
SERVICE
0
Y
AMBUSH
B
Y
Y
AMBUSH
C
AMBUSH
D
Y
AMBUSH
E
Y
F
Y
Y
Note: "Y" indicates option is enabled.
WI818G 10/05
through
1
9
ACCESS CONTROL KEYPADS
DATA
K.P. 1 K.P. 2 K.P. 3 K.P. 4
ENTRIES
blank (•)
NONE
1
Y
2
Y
3
Y
Y
Y
4
Y
5
Y
Y
6
Y
Y
7
Y
Y
8
9
Y
0
Y
B
Y
Y
Y
C
Y
D
Y
Y
E
Y
Y
F
Y
Y
Note: "Y" indicates option is enabled.
L
NAPCO Security Systems
to enter
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

Hide quick links: